The 2013 Edition of NFPA 13 will be adopted by many states and jurisdictions in January 2014. In this article we will be focusing on major changes for this latest edition of NFPA 13 and specifically in the application and use of ESFR (Early Suppression, Fast Response) sprinkler systems. Read more…
NFPA’s Fire Protection Research Foundation has released a research report on a study of flammability of lithium-ion (Li-ion) batteries in bulk storage. The results of these tests will be used to define appropriate sprinkler protection in NFPA 13 for these types of products. Three types of Li-ion batteries commonly used in various consumer products were chosen for these fire tests. They were stored in rack storage configurations up to 15 ft high. Read more…
How much do you know about fire sprinkler systems? If you are a business or a building owner, an architect, or a member of the construction industry, you may be interested in some of these commonly asked questions on sprinkler protection. Explore with us sprinkler terminology, application and use of various types of sprinkler heads, issues arising from change in occupancy or change in use, solutions to common problems, and some simple ‘rules of thumb’ Read more…
Explore with us in this extended and updated article the do’s and don’ts of ESFR sprinkler systems. We added a section on the changes of the most recent 2010 edition of FM 8-9 by FM Global, and a FAQ on the instances where in-rack sprinklers are required when the building is equipped with an ESFR system Read more…
The 2012 Fire Protection Research Foundation Medal was awarded to the research project on “High Volume/Low Speed Fans and Sprinkler Operation”. This two-phase project was conducted to study the impact of High Volume Low Speed Fans (HVLS) on fire safety. Issues raised on their usage as they relate to general sprinkler performance Read more…
Some municipal water authorities have assessed water fees related to the recovery cost of unmetered water used in the event of a fire in sprinklered buildings. However, owners and operators of unsprinklered buildings have typically not been assessed this fee – even though water usage is also unmetered during a fire. This is even more surprising given the expectation that buildings equipped with a fire protection system use less water during a fire than buildings without a fire protection system. To add to the confusion, Read more…
In January 2011, California adopted the 2010 Edition of the California Fire Code, along with the 2010 Edition of NFPA 13. This article will summarize the major differences between the storage chapters of the 2002 Edition (previously adopted standard) and 2010 Edition (newly adopted standard) of NFPA 13 published by the National Fire Protection Association. Read more…
ESFR (Early Suppression, Fast Response) sprinkler systems, have been rightfully touted as one of the best solutions and best investments in warehouse storage. But are ESFR systems an all-inclusive solution to warehouse protection? Is it the “miracle cure” to all warehousing problems? Read more…
Xtralis, a maker of Aspirating Smoke Detection (ASD) solutions, conducted a series of fire tests in a warehouse setting to demonstrate the capabilities of three smoke detection technologies, an air-sampling solution, a spot-type detector and a beam detector. Read more…
High-volume, low-speed (HVLS) fans require little energy to ventilate large commercial and industrial buildings, and their use can result in considerable cost savings to business owners. But do they compromise fire safety? What are the codes requiring? (more…)
The newest edition of NFPA 13 will be adopted as early as 2022. However, the vast majority of states and jurisdictions will be adopting the new standard in January of 2023 with California being one of these states. In this article we will be focusing [...]
Recent dust explosion accidents and their aftermath highlighted a renewed need to focus on a better understanding of the methods used in preventing these incidents. A two-phase study was commissioned by the Fire Protection Research Foundation of NFPA to develop and verify a more accurate [...]
NFPA’s Fire Protection Research Foundation (FPRF) initiated a project to determine the impact of sloped ceilings on the protection of storage with ceiling slopes steeper than 2-in-12 (equivalent to 9.5 degrees). As part of this effort, FM Global was tasked to conduct fire simulations to [...]
The newest edition of NFPA 13 (2019 Edition) will be adopted as early as 2019. However, the vast majority of states and jurisdictions will be adopting the new standard in January of 2020. In this article we will be focusing on the reformat and new [...]
In-rack sprinklers are used when ceiling sprinkler only protection is no longer adequate to protect the rack stored commodities. Well known disadvantages of current in-rack sprinkler designs are (1) additional costs and (2) additional risks of damage of the sprinkler heads during loading and unloading [...]
There is a better in good chance that the Globally Harmonized System (GHS) will impact your business. Current fire and building codes are based on NFPA standards, which – in some cases – differ from GHS regulations. With the start of key implementation deadlines already [...]